This procedure describes how to power down and lockout the Test Stand to a complete controlled energy state from AUTO CYCLE.
PROCEDURE:
- Press the
STOP AUTO CYCLE Pushbutton on the Siemens Control Panel. The START AUTO CYCLE Pushbutton will start to flash if a part is being tested.
NOTE:The Test Stand will stop in the HOME position and the START AUTO CYCLE Pushbutton will go out when the cycle is complete.
- Press the POWER OFF Pushbutton. The FAULT RESET Pushbutton and the EMERGENCY STOP Pushbutton will begin to flash.
- Pull down the Test Stand's (E-1) STATION MAIN ELECTRICAL DISCONNECT to the OFF position. This will power down the MAIN ELECTRICAL PANEL and the DRIVE/ABSORBER PANEL located on the mezzanine.
- Lockout the (E-1) STATION MAIN ELECTRICAL DISCONNECT.
- Push in the Test Stand's (A-1) STATION MAIN AIR DISCONNECT to the OFF position. A brief air rushing sound will be heard and the pressure gage to the right will go to zero.
- Lockout the (A-1) STATION MAIN AIR DISCONNECT.
- Turn the (H-1) STATION MAIN HYDRAULIC BALL VALVE to the OFF position. This supplies hydraulic fluid from the Hydraulic Power Unit to the stations hydraulic cylinders, valves and solenoids.
- Lockout the (H-1) STATION MAIN HYDRAULIC BALL VALVE.
- Turn the (H-2) STATION MAIN HYDRAULIC BALL VALVE to the OFF position. This returns hydraulic fluid from the stations hydraulic cylinders, valves and solenoids back to the Hydraulic Power Unit.
- Lockout the (H-2) STATION MAIN HYDRAULIC BALL VALVE.
- Turn the (H-3) STATION TEST OIL BALL VALVE to the OFF position. This supplies clean Transmission Test Oil to the Test Stand and is used to fill the transmission before testing.
- Lockout the (H-3) STATION TEST OIL BALL VALVE.
- Turn the (H-4) STATION TEST OIL BALL VALVE to the OFF position. This sub-system receives clean Transmission Test Oil through (H-1). It keeps this Test Oil warm by continuously circulating it through the Test Stand.
- Lockout the (H-4) STATION TEST OIL BALL VALVE.
- Turn the (H-5) STATION TEST OIL BALL VALVE to the OFF position. This returns the used Test Oil back to the Tank Farm after it has been used in the testing process.
- Lockout the (H-5) STATION TEST OIL BALL VALVE.