How to Select a Sensor on the Promess Correlation Hand Held Unit

This procedure explains how to select a sensor on the Promess Correlation Hand Held Unit. There are three different sensors to choose from.

PROCEDURE:

  1. Open the Hand Held Unit's case and remove the unit.
  2. Plug the AC adapter into an electrical outlet and then plug the cord into the Hand Held Unit to power it on.
  3. Push the SELECT SENSOR key on the Hand Held Unit.
  4. Once pushed, the list of available sensors will be displayed.
  5. Push the UP ARROW key to position the cursor next to the sensor to be selected.

    Sensor 1 is used on OP-70R-1.
    Sensor 2 is used on all OP-40 and OP-50 stations.
    Sensor 3 is used on OP-80R-2 and OP-80F-2.
  6. Next, push the SELECT key to activate the sensor selected.
  7. Verify that sensor selected is now displayed on the Hand Held Unit screen.