This procedure explains how to visually inspect and adjust Atmosphere Pilots. As contamination
in Plant Air gets into the Air Intake System it starts to build up in and plug
pilot orifices. As this occurs they will no longer burn properly or at all.
They can be adjusted to keep them burning correctly until they are cleaned or
replaced.
Always
wear heat resistant gloves, suits and face protection in accordance with plant
safety regulations for Heat Treat when working near or on any equipment in Heat
Treat or serious injury could occur.
It is critically important that all door and vestibule stack atmosphere pilots are burning and positioned properly. This is to ensure that any atmosphere gas escaping from the furnace is immediately ignited and not allowed to accumulate outside the furnace.
PROCEDURE:
If a Pilot is not lit, first light a Hand Torch and then place the Torch flame
by the Pilot to light it.
If it will not light, turn the needle valve all the way clockwise to close the gas.