This procedure is used to check the Feed Plate Clutch alignment using the Schuler
Testing Die and the Steel Test Finger. If the alignment is off, the Reverse
Die hits the Feed Fingers, causing Clutch Overloads and Collar Interruptions.
Always perform
a Paper Check before checking or adjusting the Feed Plate Clutch alignment to
eliminate the Reverse Die centering as the cause of the Feed Plate Clutch overloads.
Click
here for procedure
PROCEDURE:
- With the press stopped and the Main Menu Screen displayed, push the F2
key to bring up the Operation
Screen.
- From the Operation Screen, push the G
"Prepare Tool Change" key on the numeric keypad to unclamp
the Ejector and move the Wedge to the "0"
position.
- Push the blanks in the Curved Feed Track back up past the Blank Trap. While holding the blanks back, lift and turn the Blank
Trap to lower
it.
- Unclamp the Feed
Locking Clamp and the Small
Clamp located on the backside of the Swivel Plate.
- Move the Feed
Assembly to the Service Position.
- Unclamp the Swivel
Plate and swing it to the Service Position.
- Move the Feed
Plate Gearbox to the SERVICE POSITION.
- Remove the Obverse
and Reverse Dies.
- Place the Testing
Die in the Obverse Die housing, replace
the cover and engage the clamping
pins. Make sure the Testing Die handle is pushed in.
- Inch the press until the "0"
Feed Finger is in the work position (12 o'clock - 90°). The Feed Finger
numbers are stamped on the Feed Plate.
- Remove the "0" Feed Finger and replace it with the Steel
Test Finger.
- Move the Feed
Plate Gearbox to the WORKING POSITION.
- Pull out the Testing
Die Handle. The arbor must pass through the Steel Test Finger without
hitting it. If the arbor hits the steel finger, the Feed Plate Clutch alignment
is off and must be reset. Click
here for procedure